CAUSES OF DRIVE DC BUS UNDERVOLTAGE ALARMS SOLUTION AMP ANALYSIS

Analysis of Causes of Soot Blowing in Optical Cable Splices

Analysis of Causes of Soot Blowing in Optical Cable Splices

Splicing is required to create a continuous path for light transmission from one fiber to another. Two different methods exist for splicing fibers: Typical splice loss values (the measure of loss in optical power across the splice point) are usually lower for fusion splices (typically less than 0. Intrinsic factors, such as the refractive index of the fiber, are those that are inherent to the fiber itself. This application note discusses the splice loss measurement technique and investigates the extrinsic and intrinsic factors a ecting the splice loss measurements when joining two bare fibre strands.

Read More
Analysis of Causes of Optical Cable Splice Failures

Analysis of Causes of Optical Cable Splice Failures

 Fiber design and transmission technology have collaboratively evolved to increase bandwidth. While a small percentage, we can examine the "intrinsic" cable failures and what is done to prevent. Splice Strength, Reliability, and Packaging Since their initial deployment in communications systems more than two decades ago, optical fibers have exhibited a reliability record that is superior to that of conventional copper cables [6. Are you looking for ways to improve the performance of your fiber optic splices? If so, you've come to the right place. According to the interruption of the optical fiber of the faulty optical cable, the fault types can be divided into three types: complete optical cable interruption, partial bundle pipe interruption, and partial optical fiber interruption in a single bundle pipe. Microbends and Macrobends What Happens Microbends are small-scale distortions in the fiber core caused by uneven pressure or tightly packed fibers.

Read More
Intelligent Dehumidification Solution Design for Power Distribution Cabin

Intelligent Dehumidification Solution Design for Power Distribution Cabin

The invention discloses an intelligent power distribution cabinet dehumidification system for a power system and a dehumidification method thereof, and the dehumidification system comprises a water storage tank and a power distribution cabinet, wherein the surface of the. In operating power transmission and transformation equipment, such as switchgear cabinets, pad-mounted transformers, control cubicles, ring main units (RMUs), and outdoor terminal boxes, the compact insulation distances between components make them highly susceptible to electrical discharge. The moisture in the air condenses into water after passing through the semiconductor refrigeration unit, and is then discharged.

Read More
Solution 100G Coherent Optical Module

Solution 100G Coherent Optical Module

The Coherent 100G ZR QSFP-DCO is the industry's first dual laser QSFP28 digital coherent optics (DCO) module for single fiber, bi-directional applications – a breakthrough for network operators in access and aggregation networks. Dense Wavelength Division Multiplexing (DWDM) at 100G is no longer a premium long-haul technology—it's a mainstream foundation for metro, regional, and even data center interconnect (DCI) deployments. Its ability to multiply fiber capacity, reduce per-bit cost, and support coherent modulation makes. Nokia's 100G ZR coherent modules provide the capacity and optical reach of coherent optics in flexible, small-sized QSFP28 modules. Cisco® QSFP28 100G ZR extends 100GbE coherent links from QSFP28 ports reaching up to 80km over dark fiber and up to 300km over amplified Dense Wave Division Multiplexing (DWDM) links.

Read More
Solution Active Optical Module SFP

Solution Active Optical Module SFP

When purchasing third-party SFP optical transceivers, compatibility is often the most parameter users care about. DDM (Digital Diagnostics Monitoring) lets users check SFP modules' real-time parameters. There are three main differences between Singlemode SFP (SMF SFP) and multimode SFP (MMF SFP) ① Fiber: Singlemode fiber has a smaller core than multimode fiber, and it allows unlimited bandwidth and lower loss.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa