6-kilometre concrete structure with a cycle/pedestrian lane that stretches from Nandy Park on the East Bank of Demerara (EBD) to La Grange on the West Bank of Demerara (WBD). The Ministry of Public Works (MoPW) wishes to inform the public that continuous monitoring of settlement observation points of the Bharrat Jagdeo Demerara River Bridge has confirmed that no abnormal settlement has occurred in the bridge foundations. Shikema Dey is a Senior Research and Content Developer and experienced energy journalist with a strong record in media production and sector-focused reporting. At OilNOW, she produces in-depth coverage of Guyana's upstream developments, regulatory updates, investment activity, and regional energy. According to the Public Works Minister, Juan Edghill, during Sunday's grand commissioning ceremony, it is a dawn. WHEN the Bharrat Jagdeo Demerara River Bridge was officially commissioned on October 5, 2025, it signalled more than the completion of a long-awaited infrastructural project — it marked a new chapter in how Guyanese live, work, and connect. Photo Credit: Department of Public Information, Guyana As the day closed on October 5, seven aircrafts of the Guyana Defence Force flew past Guyana's newest bridge as it was commissioned in Demerara, Guyana.

Read More
Calculation of Relay Protection Current Setting Value

Calculation of Relay Protection Current Setting Value

Use this Protection Relay Setting Calculator to calculate pickup current, time multiplier settings (TMS), operating time, coordination time interval (CTI), and plug setting multiplier (PSM) using fault current, CT ratio, and IEC 60255 curve parameters. Pick Up Current Definition: The current level at which the relay begins to operate, overcoming the controlling force. PSM and TMS settings that are Plug Setting Multiplier and Time Multiplier Setting are the settings of a relay used to specify its tripping limits. Proper relay settings provide fault detection, coordination, & system stability, which prevents equipment damage and reduces. The protective philosophy is fundamentally grounded on the understanding that faults or abnormal operating.

Read More
Inspection of Three Types of Relay Protection Devices

Inspection of Three Types of Relay Protection Devices

Protective relay testing is usually divided into three categories: acceptance testing, commissioning, and maintenance testing. Acceptance or evaluation testing determines whether a relay is appropriate for use on a specific protection application within a power system. Distance Relays: Measure impedance to detect faults in transmission lines, aiding in fault location and isolation.

Read More
The relay protection has two sets of protection

The relay protection has two sets of protection

Primary relay or primary protection relay is the first line of power system protection whereas backup relay is operated only when primary relay fails to be operated during a fault. Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Definite time delay means that the protection operate time dose not change or depend on the. Its main purpose is to safeguard electrical equipment like transformers, generators, and transmission lines from damage due to. It functions as a watchdog by constantly surveying multiple system components including voltage, current, frequency, and phase angle.

Read More