Case Study of Intelligent Cold Aisle Construction in German Data Centers
This study proposes the container data center with the featured cold aisle containment (CAC) as effective thermal control strategy.
Read More
This study proposes the container data center with the featured cold aisle containment (CAC) as effective thermal control strategy.
Read More
The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.
Read More
This involves sealing off the aisle so that cold air does not mix with warm air within the data center. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content). Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance.
Read More
This article provides a step-by-step guide for repairing a cold joint in concrete, including preparing the surface, cleaning the cold joint, applying a bonding agent, mixing and applying a concrete patch, and smoothing and finishing the surface. The Nexans cold shrink joint Easy Tech is an all-in-one joint to be installed easily in 3 steps, bringing innovation to medium-voltage grid connections by combining simplicity, safety, and sustainability to enable the reliable energy networks of tomorrow. The wide application of fiber-to-the-home (FTTH) has promoted the rise of fiber optic fast connectors/cold connectors. The Product Specifier is the fastest resource to determine the right coupling for your application.
Read More
A fiber fast connector, also known as a mechanical splice or cold connector, is a field-installable connector that terminates fiber optic cables without requiring a fusion splicer. This comprehensive guide covers SC/APC vs SC/UPC fast connectors, selection criteria, installation best practices, compatibility considerations, and application-specific. Unlike fusion splicing, which uses heat to join two optical fibers together, cold connection uses mechanical means to create a stable and low-loss connection. Proper termination is essential for ensuring optimal performance, reducing signal loss, and maintaining the durability of the connection.
Read More+27 10 247 8396
+49 69 975 331 42
Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa