COLD PLATE COOLING INVESTIGATION FOR HIGH SPEED ELECTRONIC INTERCONNECT

Silicon Photonics Cold Plate Liquid-Cooled Switch

Silicon Photonics Cold Plate Liquid-Cooled Switch

8Tbps of bandwidth using 64 electrical lanes and incorporates an integrated liquid-cooled cold plate capable of supporting 400W+ module power consumption. Graphics processing unit (GPU) computing clusters, which serve as the basic architecture to support AI, ML, and similar applications, raise higher requirements for network transmission than central processing unit (CPU) common computing clusters. While the industry-standard OSFP (Octal Small Form-Factor Pluggable) module has successfully enabled 400Gbps, 800Gbps, and 1. 8 Tbps liquid cooled optics module that it says will help address the power and performance needed for AI data center network development. With the rapid development of AI, HPC (High-Performance Computing), and 5G, the power density of data centers has increased dramatically. " In this framework, network iteration commences with high-performance GPU scenarios to address premier business demands and subsequently broadens its support to encompass more general scenarios.

Read More
Cold aisle immersion liquid cooling system for computer room cabling systems

Cold aisle immersion liquid cooling system for computer room cabling systems

The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.

Read More
Outdoor constant temperature cabinet cold aisle high temperature resistant manufacturer

Outdoor constant temperature cabinet cold aisle high temperature resistant manufacturer

We design and manufacture electrical cabinets for areas with extreme temperature conditions, both in high temperature +250ºC and in low temperature -60ºC; ours cabinets are prepared for a high humidity concentration or a very dry environment, with the guarantee that. Our temperature-controlled electrical cabinets feature weatherproof, waterproof designs for 19" server racks, fiber distribution & cell tower equipment. Are you looking for a fast, secure and flexible outdoor enclosure solution? The intelligent modular system comprising enclosure and climate control components offers you a multitude of choices for configuration of an individual outdoor solution. We provide advanced climate controlled systems designed for diverse needs, offering reliable performance from -22 and +131 Fahrenheit (-30°C to +55°C) with constant temperatures of +/–1 K. Manufactured from food-grade 316 stainless steel, it offers excellent resistance.

Read More
10kV High Voltage Junction Box

10kV High Voltage Junction Box

Flameproof high voltage cable junction box (hereinafter referred to as junction box). He's deeply familiar with electrical standards and application needs in Europe and North America. Typical applications include: all types of power generation, on/off shore Oil & Gas power and umbilicals (uncluding hydraulics, and datacoms) and on/off shore wind farms. The rugged nature of these products also makes them suitable for heavy industrial use where high levels.

Read More
Reasons for high optical attenuation after optical cable splicing

Reasons for high optical attenuation after optical cable splicing

Intrinsic Optical Fiber Losses consist of absorption loss, dispersion loss and scattering loss caused by the structural defects or quality of the optical fiber core itself. The attenuation is a telecommunication word which refers to reduction within signal strength. This influence may be caused by the diffusion of H₂ atoms directly into the silicon (Si) structure of the optical fibers or by the formation of OH ions at locations where the fiber surface is damaged.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa