DIRECT LIQUID COOLING VS. IMMERSION COOLING FOR DATA CENTERS

Cold aisle immersion liquid cooling system for computer room cabling systems

Cold aisle immersion liquid cooling system for computer room cabling systems

The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.

Read More
Bolivia Outdoor Temperature-Controlled Cabinet Immersion Liquid Cooling Installation Solution

Bolivia Outdoor Temperature-Controlled Cabinet Immersion Liquid Cooling Installation Solution

The BESS Container 500kW 2MWh 40FT Energy Storage System Solution is a cutting-edge, highly integrated energy storage solution designed for large-scale applications. The Shenling SKY-AMECOL Data Center Cold Plate Liquid Cooling System uses a combination of onboard heat exchange and natural heat dissipation technologies. It transfers the heat generated by high heat-density components inside the server to the outside of the server chassis and then releases it. Immersion liquid cooling technology is a new cooling technology that uses liquid instead of air as the cooling medium. Compared with air, liquid has better heat transfer characteristics (greater specific heat.

Read More
Liquid Cooling of Photovoltaic Energy Storage Modules

Liquid Cooling of Photovoltaic Energy Storage Modules

Cooling of PV panels is used to reduce the negative impact of the decrease in power output of PV panels as their operating temperature increases. Different divisions of PV panel heat removal techniques can be found in the literat. Passive cooling uses natural convection and heat conduction without mechanical components to dissipate or remove heat from photovoltaic modules.

Read More
Customized Process for Low-Noise Wavelength Division Multiplexing in Data Centers

Customized Process for Low-Noise Wavelength Division Multiplexing in Data Centers

Here, we develop a novel design approach that co-optimizes inverse-designed wavelength division multiplexers and distributed Bragg gratings to achieve ultra-low crosstalk without compromising insertion loss. Current solutions are limited by trade-offs between channel spacing, crosstalk, insertion. Wavelength division multiplexing (WDM) technique plays a vital role in optical fiber com-munication. In this paper, a 4 × 1 WDM system has been developed with Vertical Cav-ity Surface Emitting LASER as optical source for each input. Close collaboration with our customers and our proven expertise across fiber, cable, and connectivity ensure you'll get solutions that are smarter, denser, faster, and easier. Abstract: We demonstrate an innovative integration of DWDM and Mode-Division Mul-tiplexing, enabling multi-dimensional transmission with 8 wavelengths and 4 modes.

Read More
Smart data centers consist of intelligent micro-modules

Smart data centers consist of intelligent micro-modules

Most recently, manufacturers have introduced the "intelligent micro module," which fuses the Internet of Things and digital and information technology. With it, independent, non-thinking components such as power, cooling, and IT infrastructures become smart . Siemens Smart Infrastructure, Cadolto Datacenter GmbH (Munich, Germany), and Legrand Data Center Solutions (Baiersdorf, Germany) are jointly unveiling a next-generation modular edge data center – a turnkey solution engineered for speed, scalability, and sustainability. In the early stage, they mainly adopted closed cold aisle combined with air cooling.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa