FIBER OPTIC SPLICER ENTRY LEVEL JOBS MAY 2026 HIRING NOW

What is the normal level of multimode optical attenuation in fiber optic cables

What is the normal level of multimode optical attenuation in fiber optic cables

For multimode fiber, the loss is about 3 dB per km for 850 nm sources, 1 dB per km for 1300 nm. This Applications Engineering Note (AE Note) discusses the criteria for properly selecting the optimal multimode fiber (MMF) for enterprise applications. The document gives details on the measurement procedure, which is based on the Electronics Industries Association Recommended Standard as published in RS. Attenuation in fiber optics is the gradual loss of light signal strength as it travels through a fiber cable.

Read More
Principle of Fiber Optic Grating for Liquid Level Measurement

Principle of Fiber Optic Grating for Liquid Level Measurement

The technique is based on the extraction of the temperature profile of the fiber by using a fiber Bragg grating (FBG) array. We propose here a liquid level sensor using a long period fiber grating (LPFG) in which direct liquid level measurement is carried out by utilising an LPFG, 100mm in length and a periodicity of 1mm. The LPFG was exposed to liquids with varying levels and the wavelength shift of a selected loss band.

Read More
Fiber optic cable entry point into the equipment room

Fiber optic cable entry point into the equipment room

The communications connection to the outside world comes into the building through what is called a "service entrance" and is terminated in the main "equipment room" or "main cross connect" which houses the electronic communications equipment which connects to the outside world. Fibre based building connectivity is not new, building entry points are not new so what is new that warrants another application note on the subject. Buildings and their communications requirements have never been so diverse which in turn requires an almost infinite degree of flexibility and. Its equipment is critical to the security, safety, and reliability of your organization. Fiber optic networks allow transmission distances of hundreds of kilometers and have an almost infinite capacity.

Read More
Indicator lights on a 5-port fiber optic switch

Indicator lights on a 5-port fiber optic switch

System activity and status can be determined through the activity of the LEDs on the switch. There are three possible LED states: no light, a steady light, and a flashing light. Switches have LEDs for indicating power status, port status,link status, error indication, troubleshooting and performance monitoring.

Read More
Can fiber optic patch cords APC and UPC be used interchangeably

Can fiber optic patch cords APC and UPC be used interchangeably

In-depth analysis of the differences between APC and UPC fiber patch cords: end face polishing angle (8° vs flat), return loss (≥60dB vs ≥50dB), application scenarios (FTTx/CATV vs data center/LAN), color identification (green vs blue) and cost differences, to help you. APC, UPC, and PC connectors define different shapes of fiber connector end faces. The main difference between APC (Angled Physical Contact) and UPC (Ultra Physical Contact) patch cords lies in their ferrule end-face geometry, which impacts their performance in fiber optic connections. A fiber optic patch cable (also called a fiber jumper or fiber patch cord) is a section of optical fiber cable with connector terminations on both ends, designed for flexible, short-distance interconnections within an optical network. The ferrule is the housing for the exposed end of a fiber, designed to be connected to another fiber, or into a transmitter or receiver. While both connector types serve the same fundamental purpose—ensuring efficient light transmission.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

🇪🇺

Germany (EU Technical Support)

+49 69 975 331 42

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa