HOW TO READ A TRACEROUTE STEP BY STEP TUTORIAL

How to read the relay protection action time

How to read the relay protection action time

The core of the action time test lies in measuring the time interval that the relay protection device takes from receiving the fault signal to issuing the tripping command. ‌Direct voltage application method‌ : Directly apply an action voltage and action current to the protection, and ensure that the phase angle between the voltage and current is within the action range. The zone1 time delay (Z1PD & Z1GD) is generally set to zero, giving instantaneous operation. Direction: Forward Typically required zone 2 reach impedances = 100% line impedances. Functions to give a desired amount of time delay before or after any point of operation in a switching sequence or protective relay system.

Read More
How to read the label on an optical module

How to read the label on an optical module

Generally, the label of an optical module provides the following information: manufacturer, serial number, speed, center wavelength, mode (single-mode/multimode), and transmission distance. To determine if your SFP (Small Form-factor Pluggable) module is single mode or multimode, you can look for specific markings or labels on the module itself. Typically, single mode SFP modules are labeled as "SM" or "single mode," while multimode modules may be labeled as "MM" or "multimode. During use, reading optical module information helps understand its real-time operating status, enabling faster troubleshooting of link abnormalities.

Read More
How to read the optical module

How to read the optical module

If you know the model or type of an optical module, you can view the section "Pluggable Modules for Interfaces" in the Hardware Description to look up parameters of the optical module, including the center wavelength, transmission distance, fiber types supported, receive optical. When the optical module on an interface is faulty, you can run the display commands to view information about the optical module. ) ships with a small EEPROM that stores two kinds of information: a fixed Serial-ID block (vendor, part number, serial number, capabilities) and—when provided—a diagnostics area (real-time temperature, voltage, TX/RX power, etc. Today, ETU-LINK will introduce how to query the information of optical module on Huawei switch.

Read More
How to aggregate bandwidth using a VLAN switch

How to aggregate bandwidth using a VLAN switch

Learn how to configure a Cisco Switch Link Aggregation using the command-line, by following this simple step-by-step tutorial, you will be able to create a new Link aggregation and configure the link aggregation in access mode or as a trunk that allows the traffic of 2. In this article, I'm going to describe how to set up Link Aggregation between two managed switches to provide connectivity, redundancy, and expanded bandwidth. Below is the output from " show interface vlan 500" FACN5KSW001# show interface vlan500 Aroud 15 physical ports of each 40Gig is associated with the vlan 500. My plan was to have my three switches use all four of the 10Gb uplink ports to a fourth "aggregator switch" so that I'd have the necessary bandwidth for a total of 12 10Gb links to the aggregator. All the physical links in a Link Aggregation Group (LAG) must operate in full-duplex mode at the same speed. You can use a LAG to directly connect two switches when the traffic between them.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa