LIQUID COOLING THEORY AND APPLICATION IN SYSTEMS DESIGN

Cold aisle immersion liquid cooling system for computer room cabling systems

Cold aisle immersion liquid cooling system for computer room cabling systems

The cooling systems technologies we install can be used in buildings housing smaller server rooms to hyperscale data centres and include free-air cooling as well as advanced liquid cooling systems. Clients expect us to not only improve their cooling and resilience (N+X) but also to reduce their total cost of ownership (TCO) and energy usage by 50%. Whether the facility has low or high density racks or a combination, it is essential to install the most appropriate data centre cooling systems to tackle the heat generated from critical IT servers, management the environmental impact of the data centre and. The Server Room Environment range includes precision air conditioning units up to 250kW, low, medium and high-density rack cooling systems up to 70kW.

Read More
Liquid Cooling of Photovoltaic Energy Storage Modules

Liquid Cooling of Photovoltaic Energy Storage Modules

Cooling of PV panels is used to reduce the negative impact of the decrease in power output of PV panels as their operating temperature increases. Different divisions of PV panel heat removal techniques can be found in the literat. Passive cooling uses natural convection and heat conduction without mechanical components to dissipate or remove heat from photovoltaic modules.

Read More
Bolivia Outdoor Temperature-Controlled Cabinet Immersion Liquid Cooling Installation Solution

Bolivia Outdoor Temperature-Controlled Cabinet Immersion Liquid Cooling Installation Solution

The BESS Container 500kW 2MWh 40FT Energy Storage System Solution is a cutting-edge, highly integrated energy storage solution designed for large-scale applications. The Shenling SKY-AMECOL Data Center Cold Plate Liquid Cooling System uses a combination of onboard heat exchange and natural heat dissipation technologies. It transfers the heat generated by high heat-density components inside the server to the outside of the server chassis and then releases it. Immersion liquid cooling technology is a new cooling technology that uses liquid instead of air as the cooling medium. Compared with air, liquid has better heat transfer characteristics (greater specific heat.

Read More
Fiber Optic Fusion Splicing Solution Design

Fiber Optic Fusion Splicing Solution Design

A practical guide to fiber optic splicing techniques, tools, and best practices from Richesin Engineering's field crew. Fiber Stripping: Selecting Precise Tools and Techniques Selecting the appropriate stripper will depend on the fiber coating diameter. This will typically be 250µm for bare fibers and 900µm for coated fibers. This process is also completed by a sophisticated tool called a Fusion Splicer, which aids in the alig ment, inspection, and curing process. Fusion fiber optic splicing provides a permanent fusion connection between fibers and offers a lower insertion loss versus mechanical splicing.

Read More
Design of Fiber Optic Vibration Sensing System

Design of Fiber Optic Vibration Sensing System

In this paper, various technologies of distributed fiber-optic vibration sensing are reviewed, from interferometric sensing technology, such as Sagnac, Mach–Zehnder, and Michelson, to backscattering-based sensing technology, such as phase-sensitive optical time domain. The fiber optic sensing technology provides data support in structural health monitoring of the macro facilities, including design, construction, and maintenance of bridges, tunnels, ports and other infrastructures. Fiber optic sensors are of two types: extrinsic and intrinsic; depending upon the sensing criteria. The sensor is based on phase-sensitive optical time-domain reflectometry (ϕ-OTDR).

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa