PDF AN APPROACH FOR THE DESIGN AND ANALYSIS OF PCB BUSBARS IN

Analysis of Causes of Soot Blowing in Optical Cable Splices

Analysis of Causes of Soot Blowing in Optical Cable Splices

Splicing is required to create a continuous path for light transmission from one fiber to another. Two different methods exist for splicing fibers: Typical splice loss values (the measure of loss in optical power across the splice point) are usually lower for fusion splices (typically less than 0. Intrinsic factors, such as the refractive index of the fiber, are those that are inherent to the fiber itself. This application note discusses the splice loss measurement technique and investigates the extrinsic and intrinsic factors a ecting the splice loss measurements when joining two bare fibre strands.

Read More
Fiber Optic Connector Insertion Loss Analysis

Fiber Optic Connector Insertion Loss Analysis

Insertion Loss is defined as the reduction in optical power between the input and output of a fiber optic link. It is expressed in decibels (dB) and calculated using the formula: IL = –10 log (Pout / Pin) Where: Lower insertion loss values indicate better optical performance. To be able to judge whether a fiber optic cable plant is good, one does a insertion loss test with a light source and power meter and compares that to an estimate of what is a reasonable loss for that cable plant.

Read More
Optical module material PCB

Optical module material PCB

Optical module PCB technology is evolving rapidly to meet the extreme demands of AI data centers and high‑speed networks. 6T, next‑generation optical modules require higher density, advanced materials, innovative thermal management, and new architectures. In simple terms, they convert electrical signals from devices like routers, switches, and servers into light signals that travel through fiber optic cables. The Printed Circuit Board (PCB) at the heart of these modules is no longer a simple substrate but a highly engineered system. This guide explains the key PCB technologies, materials, manufacturing processes, and cost considerations for 400G and 800G optical modules in 2026.

Read More
Requirements for the use of copper busbars in distribution boxes

Requirements for the use of copper busbars in distribution boxes

The IEC 61439 standard applies to busbar assemblies that will be installed in electrical applications with a voltage rating up to 1000 V (for AC) and 1500 V (for DC). In this new edition the calculation of current-carrying capacity has been greatly simplified by the provision of exact formulae for some common busbar configurations and graphical methods for others. They may be used in a variety of configurations ranging from vertical risers, carrying current to each floor of a multi-storey building, to bars used entirely within a. Research estimates that the market for copper busbar power panels in North America alone will grow by nearly 7.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

🇪🇺

Germany (EU Technical Support)

+49 69 975 331 42

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa