PDF WALK IN COLD ROOMS A PRACTITIONER''S TECHNICAL GUIDE

Methods for sealing off cold aisles in computer rooms

Methods for sealing off cold aisles in computer rooms

This involves sealing off the aisle so that cold air does not mix with warm air within the data center. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content). Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance.

Read More
Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle: Rows of racks face each other, forming a corridor where cool air is directed. The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. So we look to factors other than the economics of efficiency to evaluate the relative merits of the two. And like choosing between Marvel and DC, you must pick a side: Hot Aisle Containment (HAC) or Cold Aisle Containment (CAC). The system simply aligns server fronts (air intakes) toward a shared cold aisle, and backs (exhausts) toward a shared hot aisle.

Read More
Technical Specifications of India s 10G Long-Distance Optical Transceiver

Technical Specifications of India s 10G Long-Distance Optical Transceiver

10GBASE-LR SFP+ 1310nm 10km DOM Transceiver 10-Gigabit Ethernet links up to 10km over Single Mode fiber. Logic 0 indicates normal operation; logic 1 indicates a laser fault of some kind. It follows the SFP+ Multi-Source Agreement (MSA) and is widely used to build stable medium-distance 10G links between switches, routers, and servers. It provides a standardized method to extend network reach up to 10 kilometers (6. 3ae 10GBASE-LR/LW, and 10G Fibre Channel 1200-SM-LL-L Digital diagnostics functions are available via a 2-wire serial interface.

Read More
Technical Standards for Optical Fiber Communication Technology

Technical Standards for Optical Fiber Communication Technology

IEC Technical Committee 86 prepares International Standards for fibre optic systems, modules, devices and components intended for use with communications equipment. In particular, publications cover the area of tests, measurements and calibration ISO/IEC 17025 is a guide published by ISO. The first ITU-T Handbook related to optical fibres, Optical Fibres for Telecommunications, was published in 1984, and several others have been produced over the years. Listing of all FOA standards FOA Standard FOA-1: Testing Loss of Installed Fiber Optic Cable Plant, (Insertion Loss, TIA OFSTP-14, OFSTP-7, ISO/IEC 61280, ISO/IEC 14763, etc. Recognizing that many users find standards information to be confusing, hard to find and difficult to stay up to date on changes, the TIA's Fiber Optics Technology Consortium (FOTC) has created the FOTC Standards Explorer, a free online database that serves as a resource for anyone who wants to.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa