Methods for sealing off cold aisles in computer rooms

Methods for sealing off cold aisles in computer rooms

This involves sealing off the aisle so that cold air does not mix with warm air within the data center. By sealing out moisture, the total available cooling can be more effectively used to cool the computer servers' heat load, which is 100% sensible (no moisture content). Beyond implementing basic measures such as sealing moisture out of the data center and improving air flow, aisle containment to prevent the mixing of hot and cold air stands out as a method that can dramatically reduce energy costs, minimize hot spots and improve the carbon footprint of data. Cold aisle containment (CAC) serves as a fundamental airflow management strategy in modern Data Centres, optimising cooling efficiency and enhancing overall performance.

Read More
Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle and Hot Aisle in Computer Rooms

Cold Aisle: Rows of racks face each other, forming a corridor where cool air is directed. The hot aisle /cold aisle data center layout was originated by IBM in 1992 and it is one of the oldest ways to save energy in the data center. When implemented correctly, they improve efficiency, reduce energy consumption, extend equipment life, and enhance overall reliability. So we look to factors other than the economics of efficiency to evaluate the relative merits of the two. And like choosing between Marvel and DC, you must pick a side: Hot Aisle Containment (HAC) or Cold Aisle Containment (CAC). The system simply aligns server fronts (air intakes) toward a shared cold aisle, and backs (exhausts) toward a shared hot aisle.

Read More
Fiber optic patch panels for server racks in computer rooms

Fiber optic patch panels for server racks in computer rooms

Fiber optic patch panels are essential for organizing and managing fiber connections in data centers and structured cabling systems. AFL's portfolio includes modular and scalable solutions like the Denali High-Density Platform, LS Series, UltraSlim, U Series, and. Network architects and procurement managers must now evaluate patch panels not merely.

Read More
Quick connection cold joint

Quick connection cold joint

This article provides a step-by-step guide for repairing a cold joint in concrete, including preparing the surface, cleaning the cold joint, applying a bonding agent, mixing and applying a concrete patch, and smoothing and finishing the surface. The Nexans cold shrink joint Easy Tech is an all-in-one joint to be installed easily in 3 steps, bringing innovation to medium-voltage grid connections by combining simplicity, safety, and sustainability to enable the reliable energy networks of tomorrow. The wide application of fiber-to-the-home (FTTH) has promoted the rise of fiber optic fast connectors/cold connectors. The Product Specifier is the fastest resource to determine the right coupling for your application.

Read More
Toolless Fiber Optic Connector Cold Splicing

Toolless Fiber Optic Connector Cold Splicing

A fiber fast connector, also known as a mechanical splice or cold connector, is a field-installable connector that terminates fiber optic cables without requiring a fusion splicer. This comprehensive guide covers SC/APC vs SC/UPC fast connectors, selection criteria, installation best practices, compatibility considerations, and application-specific. Unlike fusion splicing, which uses heat to join two optical fibers together, cold connection uses mechanical means to create a stable and low-loss connection. Proper termination is essential for ensuring optimal performance, reducing signal loss, and maintaining the durability of the connection.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa