SOLARTODAY EASTERN EUROPE – THE SOLAR WHOLESALER FOR YOUR LARGE ...

For use in Eastern Europe

For use in Eastern Europe

As a largely ambiguous term, it has a wide range of geopolitical, geographical, ethnic, cultural and socio-economic connotations. Its eastern boundary is marked by the, and its western boundary is defined in various ways.

Read More
How much does a network server rack cost in Eastern Europe

How much does a network server rack cost in Eastern Europe

A half-rack (20-22U) in a Tier II facility costs EUR 200-600 per month all-in. They rent a space not only for a dedicated server, but also for one or several units in a server rack, an entire rack or several server cabinets in a closed box. Regardless of how many units are rented, clients are provided with full packages of services on the use of hardware capabilities, uptime. Whether you need a single rack at home or a thousand in a data center, you'll find the best that money can buy right here. Server racks offer the following benefits when it comes to managing your IT infrastructure: Space optimisation: By organising your hardware. Are you looking for a rack to fit your compute requirements that is designed to perform at a reasonable price? Take the guesswork out of infrastructure with HPE purpose-built racks. Compare and read user reviews of the best Rack Servers in Europe currently available using the table below.

Read More
How large a conduit should a 24-core ADSS fiber optic cable be run through

How large a conduit should a 24-core ADSS fiber optic cable be run through

While 40% is a good rule of thumb for pathways to meet present and future cable installation requirements, most telecom professionals aim for a maximum fill ratio of 70 to 80% for fiber innerduct. ADSS (All-Dielectric Self-Supporting), or ADSS - All-Dielectric Self-Supporting fiber optic cables, are employed to create light woven structure for transmission and distribution networks overhead because of many benefits such as ease of installation, lightweight structure, propriety installation. It sounds simple, but picking the wrong ADSS fiber optic cable 1 core count can cost you tens of thousands of dollars in rework, stranded capacity, or premature upgrades. This specification covers the construction all dialectic self-supporting Optical Fiber Cable (ADSS) properties for outdoor application. Premise innerduct is a flexible, non-metallic, corrugated raceway that has long been an essential conduit system for protecting fiber optic cables installed throughout telecommunications spaces and pathways. It can help isolate fiber to prevent damage from other cables or trades working in those.

Read More
Standards for Relay Protection of Large Generators

Standards for Relay Protection of Large Generators

While IEC 60255-1 and IEC 60255-26 are still under revision, the new IEC 60255-181 Standard for Frequency and ROCOF protection functions was published in February 2019. Protective relays and devices have been developed over 100 years ago to provide "last line" of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Phase Fault Protection 87 – Phase Differential Current 50 – Instantaneous Phase Overcurrent 50DT – Definite Time Overcurrent Ground Fault Protection ( High-Impedance Grounded Gens) 59N – Neutral Overvoltage with accelerated schemes 27TN – Third Harmonic Neutral Undervoltage 59D – Third Harmonic. Two prominent organizations that develop standards for generator protection are the Institute of Electrical and Electronics Engineers (IEEE) and the International Electrotechnical Commission (IEC).

Read More
Repeated grounding of large distribution boxes

Repeated grounding of large distribution boxes

The International Electrotechnical Commission (IEC) has gradually moved away from multiple earthing (also known as repeated grounding) in electrical systems. This shift is driven by safety concerns, electromagnetic compatibility, system stability, and the evolving needs of modern. Grounding is a mechanism to protect distribution equipment and people under normal operating conditions, abnormal operational (overcurrent and overvoltage) responses, and hazardous conditions such as shocks. We then analyze the behavior of ungrounded systems under ground fault conditions and introduce a new ground directional element for these systems. Whether you're a seasoned pro or just starting out, this comprehensive guide will give you practical.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

🇪🇺

Germany (EU Technical Support)

+49 69 975 331 42

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa