SUBSTATION EXPLOSION – CAUSES IMPACTS AND PROTECTION

Causes of relay protection failure

Causes of relay protection failure

Common causes include poor contact alignment, open coils, and improper relay selection for the application. There are several reasons why a relay may fail, including: Excessive current or voltage: A relay may fail if it is exposed to excessive current or voltage, which can burn out the contacts or damage the coil. Mechanical wear and tear: Relays that are used frequently can experience mechanical wear. In most cases, these issues are not caused by defective relays, but by incorrect settings, poor coordination, wiring mistakes. Like any component, relays are supplied with a number of normal operating conditions that can involve things like operating current and voltage levels, min and max operating temperatures, and also a predicted lifespan. Let's dive into the details to help you diagnose and fix issues with precision and efficiency.

Read More
Substation relay protection unit commissioning

Substation relay protection unit commissioning

Complete relay commissioning checklist for substations, covering documentation review, injection testing, CT polarity checks, and trip verification. Synchrophasor technologies are being rapidly deployed to provide high-speed, high-resolution measurements from phasor measurement units (PMUs) across the transmission systems as a tool for monitoring and post fault analysis which may lead to real-time control using PMU data in near future. The goal is to validate correct installation and adherence to design specifications, identify and fix issues before the substation is.

Read More
Lightning protection network and distribution box

Lightning protection network and distribution box

For lightning protection of distribution box transmission line, reasonable lightning protection methods shall be adopted through technical and economic comparison according to the voltage level, load nature and system operation mode of distribution box line, combined. This product is applicable to low-voltage power supply and distribution system with power grid voltage below 1000V and frequency of 50/60Hz. A power outage can result in high costs for corporate customers, for example due to production plant downtime, as well as a reduced quality of life for private customers – and an image. When there is Thor is all about protecting against the damaging effects of power. For almost 100 years, OBO has been devel-oping and producing standard-compliant lightning pro-tection components.

Read More
Thermal Relay Protection Wiring Method

Thermal Relay Protection Wiring Method

This video explains how to connect a thermal overload relay with self-hold (latching) contact to protect motors from overload and overheating. Protective Relays - Technical Seminar Nov 2016 - Copyright: IEEE 2 Abstract: Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system. We'll show you how to pick up the device, predicting the maturing of emergencies exceeding the maximum allowable current indicators.

Read More

Get In Touch

Connect With Us

📱

South Africa (Sales & Engineering HQ)

+27 10 247 8396

🇪🇺

Germany (EU Technical Support)

+49 69 975 331 42

📍

Headquarters & Manufacturing

Unit 7, Summit Place, 21 Summit Rd, Midrand, Johannesburg, 1685, South Africa